IM Products in Nigeria2026-07-29T12:30:21+05:30

Trusted Supplier of Electrical Rubber Mats in Nigeria

Buy IEC 61111:2009 and ASTM D178 compliant electrical insulating mats in Nigeria for transmission network, distribution substations, oil and gas companies, NLNG, Dangote Refinery, and large-scale industrial projects.
0+
Years in Business
0+
Countries Exported
0+
Happy Clients
0+
Successful Projects

Duratuf Premium Electrical Rubber Mat in Nigeria for High-Voltage Safety

IEC electrical rubber mat
ASTM electrical insulating mat

Nigeria’s electricity sector is governed by NERC as the regulatory authority, NEMSA for technical standards enforcement, inspection, and certification, and TCN for the national transmission grid. NEMSA’s enforcement framework uses IEC Standards and Specifications as its primary legal instruments, making IEC 61111:2009 the applicable standard for electrical insulating mats across Nigeria’s utility, oil and gas, and industrial sectors. Nigeria’s electricity supply and installation standards regulations also carry normative references to IEC standards, aligning the country’s technical baseline with international frameworks. Any electrical installation contractor or facility operating within NEMSA’s jurisdiction is required to use safety equipment that meets these standards.

Nigeria’s grid operates at 330kV and 132kV at the transmission level, stepping down through TCN’s network to 33kV and 11kV across the DisCo distribution system. The 11 DisCos manage extensive distribution substation networks where insulating mats are a mandatory safety layer for switchgear and operator areas. Beyond the utility network, Nigeria’s oil and gas sector drives substantial industrial electrical safety requirements. NNPC Limited, Shell Nigeria, TotalEnergies E&P Nigeria, Chevron Nigeria, and ExxonMobil Nigeria all operate large electrical infrastructure across the Niger Delta region. Nigeria LNG on Bonny Island and the Dangote Petroleum Refinery at Lekki, Lagos; both represent significant new demand for certified electrical safety equipment at scale.

Duratuf electrical insulating mats are type-tested to IEC 61111:2009 and ASTM D178 across Class 0 to Class 4, covering working voltages from 1.0 kV to 36.0 kV. The IEC 61111:2009 range is aligned with NEMSA’s enforcement framework and the Nigerian Electricity Supply and Installation Standards Regulations. ASTM D178 mats are available for international joint venture projects and oil and gas specifications that reference American norms, common across Niger Delta IOC contracts and international EPC agreements. Both ranges are manufactured from elastomers free from any insertion, are flame retardant, and oil resistant, properties directly relevant to Nigeria’s dominant industrial buyer.

Certifications & Memberships

Technical Specification of Electrical Insulating Mat

IEC 61111:2009 Electrical Rubber Mat Specifications

Product CodeClassMax Use VoltageAC Proof VoltageWithstand VoltageRecom. Thickness
IM-IEC-C001.0 kV5.0 kV10.0 kV2.0 mm
IM-IEC-C117.5 kV10.0 kV20.0 kV2.0 mm
IM-IEC-C2217.0 kV20.0 kV30.0 kV3.0 mm
IM-IEC-C3326.5 kV30.0 kV40.0 kV4.0 mm
IM-IEC-C4436.0 kV40.0 kV50.0 kV5.0 mm

Customisation available: thickness up to 14 mm, width up to 1,220 mm, length up to 15 m. Contact us for cut-to-size orders.

ASTM D178 Electrical Insulating Mat Specifications

Product CodeClassMax Use VoltageAC Proof VoltageDielectric VoltageRecom. Thickness
IM-ASTM-C001.0 kV5.0 kV10.0 kV3.2 mm
IM-ASTM-C117.5 kV10.0 kV20.0 kV4.8 mm
IM-ASTM-C2217.0 kV20.0 kV30.0 kV6.4 mm
IM-ASTM-C3326.5 kV30.0 kV40.0 kV9.5 mm
IM-ASTM-C4436.0 kV40.0 kV50.0 kV12.7 mm

Unless specified, ASTM D178 mats are supplied as Type I. Type II variants with ozone, flame, or oil resistance are available on request.

Want an Immediate Exclusive Quote?
Our team of specialists respond within 60 minutes!

Applications of Electrical Rubber Mat in Nigeria

Electrical insulating mats are required wherever operators work near live equipment at system voltage. Duratuf electrical insulating mats are used across the following installation types in Nigeria:

  • TCN transmission substations at 330kV and 132kV, and DisCo distribution substations at 33kV and 11kV across all six geopolitical zones
  • NNPC Limited, Shell Nigeria, TotalEnergies E&P Nigeria, Chevron Nigeria, and ExxonMobil Nigeria oil and gas facility electrical control rooms across the Niger Delta
  • Nigeria LNG (NLNG) plant electrical switchgear and control rooms at Bonny Island
  • Dangote Petroleum Refinery electrical utility infrastructure and control rooms at Lekki, Lagos
  • Onne Oil and Gas Free Zone facility electrical maintenance areas in Rivers State
  • Dangote Cement, BUA Cement, and Lafarge Africa plant HT/LT control rooms and switchgear areas across production sites
  • Independent Power Producer (IPP) and National Integrated Power Project (NIPP) gas turbine plant electrical control rooms
  • Data center and telecommunications infrastructure electrical rooms in Lagos and Abuja
  • Federal Airports Authority of Nigeria (FAAN) airport electrical maintenance areas at Lagos, Abuja, and Kano.
Features of IEC 61111:2009 Electrical Insulating Mats | Duratuf

Features of IEC 61111:2009 Electrical Insulating Mats | Duratuf

Exclusive Features Of Duratuf Electrical Insulation Mats

Icon of 100% Shock Proof protection

High Di-electric Strength

Icon of ERDA Test Certification

Quality-Certified

Icon of Safety Audit Compliant

Safety-Audit Passed

Icon of Chemical & Flame Retardant

Chemical, UV, Ozone and Flame Retardant

Icon of Moisture & Ozone Resistant

Moisture and Water Resistant

Icon of Ready-Stock Inventory

Up to 10,000 sq m Ready Stock

Icon of Expert Consultation

Free Expert Guidance

Icon of Competitive Pricing

Competitive Pricing

Icon of Proactive Customer Support

End-to-End Customer Support

Our Clientele

Frequently Asked Questions

Nigeria’s DisCo distribution network operates at 33kV and 11kV. For 33kV substation and switchgear work, Class 3 is the correct specification – max use voltage 26.5kV, AC proof voltage 30.0kV. For 11kV distribution substation work, Class 2 applies – max use voltage 17.0kV, AC proof voltage 20.0kV.

Yes. Our IEC 61111:2009 mats cover Class 0 to Class 4 and are both flame retardant and oil resistant, the two properties most directly relevant to Niger Delta oil and gas electrical room specifications. ASTM D178 Type II mats with additional ozone, flame, or oil resistance are also available for international IOC project specifications.

The order processing time is influenced by the product and the quantity that you want to purchase. For 0-300 sq. meters, it takes 3-4 weeks. Whereas, for 300-700 sq. meters, it takes 4-6 weeks. On the other hand, beyond that, the order processing time is 6-8 weeks.

Every order includes a type-test certificate confirming compliance with IEC 61111:2009 or ASTM D178, a product datasheet, and labelled packaging identifying product code, voltage class, and dimensions. These documents are suitable for NEMSA inspection submissions, DisCo and TCN project submittals, oil and gas HSE audits, and international EPC contractor documentation packages.

Buying Electrical Insulating Mats for a Nigeria Project?
Share your system voltage, installation type, and quantity. We confirm the correct class, stock availability from our Dubai warehouse along with pricing in a single response.
Translate