Skip to content

Top Supplier of Electrical Rubber Mat in South Korea

Buy IEC 61111:2009 and ASTM D178 compliant electrical insulating mats in South Korea for KEPCO distribution network, semiconductor fabrication companies, nuclear power plants, shipbuilding yards, and heavy industrial complexes at best price.

Product range

Duratuf Premium Electrical Insulating Mat in South Korea for High-Voltage Safety

South Korea’s electrical safety framework involves several coordinating authorities. KEPCO manages national power supply. MOTIE sets policy and legislation. KESCO handles direct safety inspection and investigation. KOSHA governs occupational safety certification for industrial equipment. Korean Industrial Standards (KS), developed by KATS and harmonized with IEC international standards, form the technical framework for electrical safety equipment across the country. KEPCO’s distribution network operates at 22.9kV, a voltage level that places most substation and switchgear room work within the Class 3 specification range of IEC 61111:2009 (max use voltage 26.5kV).

IEC electrical rubber mat

IEC 61111:2009

IEC 61111 Insulating Rubber Mats

Designed for designated work areas around electrical equipment in substations, power generation, renewable energy and industrial process-control environments.

Key features

  • Class range shown as 0–4
  • Multiple thickness options
  • Textured or ribbed surfaces
  • Datasheet-led class selection
  • Manufacturer test documentation
  • Custom sizes may be available
ASTM electrical insulating mat

ASTM D178

ASTM D178 Switchboard Mats

Insulating mats for industrial electrical work areas. Select the appropriate construction and grade according to the applicable specification and environmental exposure.

Key features

  • Voltage classes listed from 0–4
  • Thickness depends on class
  • Grade depends on work environment
  • Type I and Type II options
  • Oil, ozone or flame-resistant grades may be specified
  • Technical documentation available to request

Trusted & Certified

Standards that stand behind every mat.

Technical reference

Technical Specification of Electrical Rubber Mats

Choosing the correct insulating mat depends on your maximum system voltage and working conditions

StandardClass RangeMaximum Use VoltageAC Proof VoltageDi-electric StrengthThicknessColor
IEC 611110 to 4Up to 36kV5.0 kV - 40.0 kV10.0 kV to 50.0 kV2mm to 5mmBlack
ASTM D1780 to 4Up to 36kV5.0 kV - 40.0 kV10.0 kV to 50.0 kV3.2mm to 12.7mmBlack

Talk to our Industrial Safety Expert

Talk to our team about the right insulating solution.

Application

Applications of Electrical Rubber Mat in South Korea

Electrical insulating mats are required wherever operators work near live electrical equipment and where electrical accident can occur anytime. Duratuf electrical insulating mats can be used across the following installation in South Korea:

Our Clients

We Are Proud To Work With

Our clients are not just business collaborations but relationships we value for a lifetime. We commit ourselves to manufacture features rich high quality insulating mats.

Why Duratuf

Why Choose Duratuf for Electrical Safety Matting in South Korea?

Use product documentation and a site-specific assessment to decide whether a particular Duratuf mat is right for the job.

Regional Coverage

Explore Duratuf in Asia

Find country-specific information on electrical insulating mats and industrial safety solutions.

Country Directory

Asia

23Countries

FAQs

Questions to settle before procurement.

Electrical safety mat selection is standards-led. The answers below are intentionally qualified; check current manufacturer documents and local requirements before specifying.

KEPCO operates South Korea’s distribution network at 22.9kV. For work at 22.9kV installations; switchgear rooms, transformer bays, and substation operator areas, Class 3 is the correct specification. Class 3 has a max use voltage of 26.5kV, AC proof voltage of 30.0kV, and withstand voltage of 40.0kV, providing the required safety margin above the 22.9kV working voltage.

Yes. Semiconductor fabs require certified electrical safety equipment for utility substations, HT/LT control rooms, and cleanroom support electrical infrastructure. Our IEC 61111:2009 mats are type-tested across Class 0 to Class 4 and supplied with type-test certificates and product datasheets suitable for facility EHS audit and procurement documentation.

Yes. Our IEC 61111:2009 electrical mats are rated for working temperatures of -25°C to +55°C, which covers South Korea’s full seasonal range, from winter lows at inland and northern facilities to summer highs at southern coastal industrial complexes. For indoor air-conditioned electrical rooms, which is the standard environment across most Korean industrial and utility installations, seasonal temperature variation does not affect dielectric performance.

Every order includes a type-test certificate confirming compliance with IEC 61111:2009 or ASTM D178, a product datasheet, and labelled packaging with product code, voltage class, and dimensions. These are suitable for EHS audit documentation, facility procurement records, and project safety submittals. Contact us if your project requires a specific documentation format.