Top Supplier of Electrical Rubber Mat in Sri Lanka for Industrial Safety

Buy IS 15652 Indian standard and IEC 61111 International Standard Electrical insulating Mat in Sri Lanka at Best Price

Duratuf Products Pvt. Ltd. is a Kolkata, India based industrial safety solutions company supplying IEC 61111:2009 and IS 15652: 2006 electrical insulating mats to Sri Lanka’s power utilities, BOI manufacturing zones and other industrial sectors. Sri Lanka’s electricity regulations, governed by the Ceylon Electricity Board, explicitly reference IEC standards as the accepted compliance benchmark for materials used across generation, transmission, distribution and other high-voltage electrical areas.

We supply electrical mats, manufactured and tested to IEC 61111:2009, covering the full voltage class range from Class 0 (1 kV) to Class 4 (36 kV). For Indian EPC contractors and project developers working in Sri Lanka who follow Indian procurement norms, we also supply XVOLT mats manufactured and type-tested to IS 15652:2006. Every order ships with full type test documentation, voltage class certificates, and product datasheets for CEB tender submissions and facility safety audits.

0+
Years in Business
0+
Countries Exported
0+
Happy Clients
0+
Successful Projects

Explore Our Electrical Insulating Mats for Sri Lanka’s Industrial Safety

All our mats are voltage class tested from Class 0 (1 kV) through Class 4 (36 kV), with full type test documentation available for CEB tender submissions, BOI facility safety audits, and industrial procurement requirements.

IEC 61111:2009 Insulating Rubber Mats

Electrical Rubber mats for IEC 61111 standards are used for high voltages protection and are used in power generation, substations, switchboard room, electrical panels, generator yards, and industrial relays.

Key Features:

  • Classes 0 to 4
  • Rated for voltages up to 36kV
  • Thickness range: 2mm-5mm
  • Anti-slip surface finish
  • Flame-retardant material
  • High dielectric strength

These mats provide reliable insulation in control rooms and areas with live electrical equipment.

IEC 61111 Insulating Mat
IS 15652 Insulating Mat

IS 15652:2006 Electrical Insulating Mats

Mats manufactured and type-tested to IS 15652:2006, the standard covers three voltage classes, each tested for dielectric strength, flame retardance, and resistance to oils, acids, and alkalis.

Key Features:

  • Class A (3.3 kV working), Class B (11 kV working), Class C (33 kV working)
  • Thickness: 2.0 mm to 3.0 mm depending on class
  • ISI Marked under BIS Certification
  • Flame retardant: self-extinguishing within 5 seconds
  • Resistant to oils, dilute acids and alkalis
  • Tensile strength: 15 MPa minimum
  • Suitable for switchgear rooms, HT/LT panels, transformer bays and substations

Explore Our Electrical Insulating Mats for Sri Lanka’s Industrial Safety

All our mats are voltage class tested from Class 0 (1 kV) through Class 4 (36 kV), with full type test documentation available for CEB tender submissions, BOI facility safety audits, and industrial procurement requirements.

IEC 61111 Insulating Mat

IEC 61111:2009 Insulating Rubber Mats

Electrical Rubber mats for IEC 61111 standards are used for high voltages protection and are used in power generation, substations, switchboard room, electrical panels, generator yards, and industrial relays.

Key Features:

  • Classes 0 to 4
  • Rated for voltages up to 36kV
  • Thickness range: 2mm-5mm
  • Anti-slip surface finish
  • Flame-retardant material
  • High dielectric strength

These mats provide reliable insulation in control rooms and areas with live electrical equipment.

IS 15652 Insulating Mat

IS 15652:2006 Electrical Insulating Mats

Mats manufactured and type-tested to IS 15652:2006, the standard covers three voltage classes, each tested for dielectric strength, flame retardance, and resistance to oils, acids, and alkalis.

Key Features:

  • Class A (3.3 kV working), Class B (11 kV working), Class C (33 kV working)
  • Thickness: 2.0 mm to 3.0 mm depending on class
  • ISI Marked under BIS Certification
  • Flame retardant: self-extinguishing within 5 seconds
  • Resistant to oils, dilute acids and alkalis
  • Tensile strength: 15 MPa minimum
  • Suitable for switchgear rooms, HT/LT panels, transformer bays and substations

Compliance & International Certifications

All our insulating rubber mats are tested according to globally recognised standards

Voltage Comparison for Insulating Mats: Technical Specification

Choosing the right insulating mat depends on your maximum system voltage and working conditions.

StandardClass RangeMaximum Use VoltageAC Proof VoltageDielectric StrengthThicknessColor
IEC 61111:2009Class 0 to Class 41.0 kV to 36.0 kV5.0 kV to 40.0 kV10.0 kV to 50.0 kV2.0 mm to 5.0 mmBlack
IS 15652:2006Class A, B, C3.3 kV to 33.0 kV10.0 kV to 36.0 kV30.0 kV to 65.0 kV2.0 mm to 3.0 mmBlack & Blue
If you are unsure which electrical insulating rubber mat is suitable for your industrial use and project, our technical team is here to help you select the correct class and thickness.
Talk to our Industrial Safety Expert

Applications of Insulating Rubber Mats in Sri Lanka

Sri Lanka’s power sector and export-driven industrial economy create specific electrical safety requirements across utilities, manufacturing, and port infrastructure. Our insulating mats are used across these environments:

  • CEB Substations and Switching Stations
    CEB’s transmission and distribution substations across Colombo, Kandy, and Trincomalee require IEC 61111 rated mats at control panels and switchgear bays as standard electrical safety compliance for all operating personnel.

  • Garment and Textile Manufacturing Zones
    BOI export processing zones in Colombo, Biyagama, and Katunayake run large electrical installations for production lines. Voltage-rated mats at HT switchboards and generator rooms ensure operator protection across every shift.

  • Tea Processing and Plantation Industry
    Tea factories across Kandy and Nuwara Eliya operate electrical drying, rolling, and processing equipment that requires properly rated insulation flooring at panel fronts and motor control stations.

  • Colombo Port and Maritime Infrastructure
    Colombo Port’s cargo handling and container terminal operations involve high-load electrical equipment. IEC 61111 mats at crane control rooms, shore power panels, and substation bays protect workers handling live systems.

  • Industrial Zones and Infrastructure Projects
    Large infrastructure and energy projects across Galle, Jaffna, and Trincomalee involve temporary and permanent electrical installations where IEC or IS-rated insulating mats protect workers in site electrical rooms and switchgear areas.

Why Choose Duratuf for Electrical Safety Mats in Sri Lanka?

16+ Years of Industry Knowledge

We have been serving industries with our quality-assured insulating mats for the past 16+ years.

Icon of ERDA Test Certification

Legally Required Quality Assurance

Our insulating mats are compliant with the IEC 61111:2009 and ASTM D178 standards.

Customization Capability

We offer customization option for sizes and thicknesses as per your project requirements.

Expertise in Bulk Deliveries

With our efficient supply chain team and well-managed inventory we ensure fulfillment of large-volume orders.

Technical Assistance

From installation to maintenance, we ensure you get end-to-end reolution of queries and support throughout your purchase journey.

Our Clientele

Buy Insulating Rubber Mats in Sri Lanka

65+
Countries
16+
Years
4,142+
Customers

For IEC 61111 and IS 15652 insulating mats in Sri Lanka, connect with us for bulk supply, datasheets, and pricing.

Frequently Asked Questions

Sri Lanka’s Electricity Safety Regulations explicitly reference IEC standards as the accepted compliance benchmark for materials used across power infrastructure. This makes IEC 61111:2009 the correct standard for insulating mats in CEB substations, switching stations, and distribution facilities.

Yes. CEB procurement requires type test reports from accredited independent testing laboratories. Our electrical mats come with IEC 61111:2009 type test certificates issued by accredited labs, along with product datasheets and traceability documentation that meet CEB’s tender submission requirements.

For 33 kV substations, IS 15652 Class C or IEC 61111 Class 3 mats are the correct specification. For 11 kV installations, Class B or IEC Class 2 applies. For LT panels and distribution boards up to 3.3 kV, Class A or IEC Class 1 covers the requirement. Share your system voltage and our technical team will confirm the right class.

Yes. Indian EPC contractors who specify IS 15652 as their procurement standard can use XVOLT mats, which are manufactured and type-tested to IS 15652:2006 and carry ISI marking under BIS certification. We supply these with full compliance documentation through established India-Sri Lanka export logistics.

Yes. We supply bulk rolls and custom cut lengths to Sri Lanka from our Bhiwadi facility. Every order includes type test certificates, product datasheets, and packing documentation suitable for Sri Lanka Customs clearance and site safety records.