Skip to content

Top Supplier of Electrical Insulating Rubber Mats for Iron, Steel & Metal Processing Industry

Protect your workers from electrical Hazards with IS 15652/ IEC 61111 / ASTM D178 Standards Electrical Safety Mats | Tested up to 36,000V

IS 15652 · IEC 61111 · ASTM D178
Choose by standard, class and application.

The challenge

Protect Personnel Working Around High-Voltage Electrical Equipment in Iron, Steel and Metal Processing Plants

Iron, steel and metal processing plants run on massive electrical loads. Electric arc furnaces, induction furnaces, rolling mills, continuous casting units and metal processing lines are all powered through HT and LT switchgear panels, motor control centres and substations, where electrical workers operate daily around 33kV/11kV/6.6kV switchgear and 415V distribution boards. Even a brief insulation failure in these high-energy environments can lead to severe electric shock, injury, fatality or a costly production shutdown.

When technicians work near live switchgear, control panels or transformers in iron, steel & metal processing units, the risk of electric shock increases very significantly, particularly in harsh industrial conditions.

Our electrical insulating rubber mats create a safe and compliant working zone around live electrical equipment, helping iron and steel plant EHS managers and maintenance teams protect personnel, reduce risk and meet IS 15652 / IEC 61111 / ASTM D178 safety standards.

  1. 01 Electric shock risk near furnace control panels, rolling mill MCCs and 33kV/11kV substations
  2. 02 Metal dust and scale particles accumulating on mat surfaces and reducing grip over time
  3. 03 Radiant heat from electric arc furnaces degrading non-certified rubber mats
  4. 04 Live work on rolling mill drives, casting panel controls and process line switchgear
  5. 05 Strict regulatory and third-party safety audit requirements for certified electrical safety equipment

Trusted & Certified

Standards that stand behind every mat.

The Range

Four mats. One job — keep operators alive.

Deployment zones

Application of Electrical Insulating Mats in Iron, Steel & Metal Processing Industry

Electrical insulating matting may be considered at work positions where personnel operate near electrical equipment. The correct specification depends on the task, equipment, standard and assessed hazard.

Discuss your site ↗
  • Transmission towers at sunset

    01Electric Arc Furnace Control Rooms

    • Substation equipment and pipework

      02Main Receiving Substations

      • Aerial view of an outdoor solar and switchyard site

        03Rolling Mill MCC Rooms

        • Engineer reviewing panel drawings

          04Continuous Casting Control Areas

          • Transmission towers at sunset

            05Induction Furnace Electrical Rooms

            • Technician working on control equipment

              06Metal Processing Line MCCs

              • Engineer viewing an electrical layout on screen

                07LT Switchboards and Control Rooms

                • Solar panels under a cloudy sky

                  08Captive Power Plant and DG Sections

                  Iron, Steel & Metal facilities · Selection assistant

                  Find the right insulating mat class for your work area.

                  Choose the facility and system voltage to view a starting reference for your specification conversation. Always confirm the applicable standard and current test documents before procurement.

                  Insulating Mat Selector

                  Six questions · Standard, class and stock match

                  • IS 15652
                  • IEC 61111
                  • ASTM D178

                  Why Duratuf

                  Why Choose Duratuf for Rubber Electrical Insulating Mats for Iron & Steel Plants

                  Use product documentation and a site-specific assessment to decide whether a particular Duratuf mat is right for the job.

                  Our Clients

                  We Are Proud To Work With

                  Our clients are not just business collaborations but relationships we value for a lifetime. We commit ourselves to manufacture features rich high quality insulating mats.

                  FAQs

                  Questions to settle before procurement.

                  Electrical safety mat selection is standards-led. The answers below are intentionally qualified; check current manufacturer documents and local requirements before specifying.

                  Insulating mats should be installed in front of main receiving substations (33kV/11kV), rolling mill and continuous casting MCC panels (6.6kV/3.3kV), furnace control rooms, induction furnace power supply panels, LT distribution boards and any electrical room or relay panel where workers access live electrical equipment.

                  For 33kV main receiving substations, IS 15652 Class C (33kV working voltage) or IEC 61111 Class 4 (36kV maximum use voltage) is required. For 11kV systems, IS 15652 Class B (11kV working voltage) or IEC 61111 Class 2 (17kV maximum use voltage) is the correct specification.

                  Standard IS 15652 and IEC 61111 mats are designed for indoor electrical environments. For locations near electric arc furnaces with high radiant heat, ASTM D178 Type II mats with flame-retardant or heat-resistant properties should be specified. Mats should not be placed in direct contact with extreme heat sources and should be inspected more frequently in high-temperature zones.

                  Metal dust and scale particles can accumulate on mat surfaces and reduce grip. The anti-skid ribbed surface allows regular cleaning. The dielectric properties of certified rubber mats are not affected by surface metal dust when the mat material is undamaged. Regular inspection and prompt replacement of damaged mats is essential in steel plant environments.

                  For 6.6kV rolling mill motor control centres, IS 15652 Class B (11kV working voltage) or IEC 61111 Class 1 (7.5kV maximum use voltage, technical minimum) is appropriate. IEC Class 2 (17kV maximum use voltage) provides a larger safety margin and is recommended where specification allows.

                  Yes. IS 15652, IEC 61111 and ASTM D178 certified mats are accepted in statutory electrical safety inspections in India and internationally. Mats with valid type test certificates support compliance during Factory Act audits, Factory Inspector visits and third-party EHS assessments. Always request a test certificate when procuring.