IS 15652:2006
The flagship general-purpose mat for Indian substations and panel rooms.
Explore X-VoltProtect your workers from electrical Hazards with IS 15652/ IEC 61111 / ASTM D178 Standards Electrical Safety Mats | Tested up to 36,000V
IS 15652 · IEC 61111 · ASTM D178
Choose by standard, class and application.
The challenge
Iron, steel and metal processing plants run on massive electrical loads. Electric arc furnaces, induction furnaces, rolling mills, continuous casting units and metal processing lines are all powered through HT and LT switchgear panels, motor control centres and substations, where electrical workers operate daily around 33kV/11kV/6.6kV switchgear and 415V distribution boards. Even a brief insulation failure in these high-energy environments can lead to severe electric shock, injury, fatality or a costly production shutdown.
When technicians work near live switchgear, control panels or transformers in iron, steel & metal processing units, the risk of electric shock increases very significantly, particularly in harsh industrial conditions.
Our electrical insulating rubber mats create a safe and compliant working zone around live electrical equipment, helping iron and steel plant EHS managers and maintenance teams protect personnel, reduce risk and meet IS 15652 / IEC 61111 / ASTM D178 safety standards.
Trusted & Certified










The Range
IS 15652:2006
The flagship general-purpose mat for Indian substations and panel rooms.
Explore X-Volt
IEC 61111:2009
The flagship general-purpose mat for Indian substations and panel rooms.
View Technical Specs
ASTM-D178
The flagship general-purpose mat for Indian substations and panel rooms.
Discover X-Volt
EProtect
The flagship general-purpose mat for Indian substations and panel rooms.
Find Your Mat ClassDeployment zones
Electrical insulating matting may be considered at work positions where personnel operate near electrical equipment. The correct specification depends on the task, equipment, standard and assessed hazard.
Iron, Steel & Metal facilities · Selection assistant
Choose the facility and system voltage to view a starting reference for your specification conversation. Always confirm the applicable standard and current test documents before procurement.
Six questions · Standard, class and stock match
An insulating mat is one layer of protection. It does not replace isolation, earthing, safe work procedures or other PPE. Final selection is subject to installation conditions and a qualified electrical safety assessment. Figures marked “verify” are being confirmed against licensed copies of the standards.
Why Duratuf
Use product documentation and a site-specific assessment to decide whether a particular Duratuf mat is right for the job.
Our insulating mats are engineered to withstand heat, dust, vibration, and heavy industrial usage.
Our Insulating rubber mats are designed for 24/7 plant operations without compromising insulation performance.
Duratuf insulating mats are highly abrasion-resistant to wear and tear in high-movement industrial zones.
Each insulating mat is tested to ensure stable dielectric strength and long-term reliability.
Our safety mats help iron and steel plants meet IS / IEC / ASTM standards and internal safety protocols.
Our Clients
Our clients are not just business collaborations but relationships we value for a lifetime. We commit ourselves to manufacture features rich high quality insulating mats.
























FAQs
Electrical safety mat selection is standards-led. The answers below are intentionally qualified; check current manufacturer documents and local requirements before specifying.
Insulating mats should be installed in front of main receiving substations (33kV/11kV), rolling mill and continuous casting MCC panels (6.6kV/3.3kV), furnace control rooms, induction furnace power supply panels, LT distribution boards and any electrical room or relay panel where workers access live electrical equipment.
For 33kV main receiving substations, IS 15652 Class C (33kV working voltage) or IEC 61111 Class 4 (36kV maximum use voltage) is required. For 11kV systems, IS 15652 Class B (11kV working voltage) or IEC 61111 Class 2 (17kV maximum use voltage) is the correct specification.
Standard IS 15652 and IEC 61111 mats are designed for indoor electrical environments. For locations near electric arc furnaces with high radiant heat, ASTM D178 Type II mats with flame-retardant or heat-resistant properties should be specified. Mats should not be placed in direct contact with extreme heat sources and should be inspected more frequently in high-temperature zones.
Metal dust and scale particles can accumulate on mat surfaces and reduce grip. The anti-skid ribbed surface allows regular cleaning. The dielectric properties of certified rubber mats are not affected by surface metal dust when the mat material is undamaged. Regular inspection and prompt replacement of damaged mats is essential in steel plant environments.
For 6.6kV rolling mill motor control centres, IS 15652 Class B (11kV working voltage) or IEC 61111 Class 1 (7.5kV maximum use voltage, technical minimum) is appropriate. IEC Class 2 (17kV maximum use voltage) provides a larger safety margin and is recommended where specification allows.
Yes. IS 15652, IEC 61111 and ASTM D178 certified mats are accepted in statutory electrical safety inspections in India and internationally. Mats with valid type test certificates support compliance during Factory Act audits, Factory Inspector visits and third-party EHS assessments. Always request a test certificate when procuring.