X-Volt Insulating Mats
IS 15652:2006
The flagship general-purpose mat for Indian substations and panel rooms.
Explore X-VoltProtect your workers from electrical Hazards with IS 15652 / IEC 61111 / ASTM D178 Standards, Certified Electrical Safety Mats | Tested up to 36,000V
IS 15652 · IEC 61111 · ASTM D178
Choose by standard, class and application.
The challenge
Mining and mineral processing operations depend on continuous high-voltage electrical systems to power crushers, conveyors, ball mills, screening units, pumps and processing plants. Electrical workers and maintenance teams operate daily around 33kV/11kV substations, 6.6kV and 3.3kV motor control centres and 415V distribution boards across surface and underground sites. Even a small insulation failure in these environments can lead to severe electric shock, injury, fatality or a costly operational shutdown.
In mining operations, the electrical risk is very high because of heavy mineral dust, moisture from dewatering systems and underground conditions, intense floor vibration from heavy equipment and remote site locations where emergency response is slow. Electrical safety in this environment is not optional; it is critical to protect workers and maintain uninterrupted mining output.
Our electrical insulating rubber mats create a safe and compliant working zone around live electrical equipment, helping mining company EHS managers and maintenance teams protect personnel, reduce risk and meet stringent IS 15652 / IEC 61111 / ASTM D178 safety standards.
Trusted & Certified










The Range
IS 15652:2006
The flagship general-purpose mat for Indian substations and panel rooms.
Explore X-Volt
IEC 61111:2009
The flagship general-purpose mat for Indian substations and panel rooms.
View Technical Specs
ASTM-D178
The flagship general-purpose mat for Indian substations and panel rooms.
Discover X-Volt
EProtect
The flagship general-purpose mat for Indian substations and panel rooms.
Find Your Mat ClassDeployment zones
Electrical insulating matting may be considered at work positions where personnel operate near electrical equipment. The correct specification depends on the task, equipment, standard and assessed hazard.
Mining & Minerals facilities · Selection assistant
Choose the facility and system voltage to view a starting reference for your specification conversation. Always confirm the applicable standard and current test documents before procurement.
Six questions · Standard, class and stock match
An insulating mat is one layer of protection. It does not replace isolation, earthing, safe work procedures or other PPE. Final selection is subject to installation conditions and a qualified electrical safety assessment. Figures marked “verify” are being confirmed against licensed copies of the standards.
Why Duratuf
Use product documentation and a site-specific assessment to decide whether a particular Duratuf mat is right for the job.
Our insulating mats are built to perform in rugged mining environments with dust, vibration, and moisture exposure.
Duratuf safety mats are designed to maintain insulation performance even in 24/7 mining operations.
Our insulating rubber mats are highly resistant to wear and abrasion in high-traffic work zones.
At Duratuf, we tested and certified each insulating mat to ensure stable dielectric strength and dependable insulation over time.
Our electrical safety mats help mining companies meet electrical safety standards and internal safety policies with confidence.
Our Clients
Our clients are not just business collaborations but relationships we value for a lifetime. We commit ourselves to manufacture features rich high quality insulating mats.
























FAQs
Electrical safety mat selection is standards-led. The answers below are intentionally qualified; check current manufacturer documents and local requirements before specifying.
In mining industries, insulating mats should be installed in front of main surface substations (33kV/11kV), crushing and screening plant control panels, conveyor drive MCCs, mineral processing plant switchgear, underground electrical substations, pump house and dewatering panels and any control room where workers access live electrical equipment.
For 33kV main surface substations, IS 15652 Class C (33kV working voltage) or IEC 61111 Class 4 (36kV maximum use voltage) is required. For 11kV underground and surface substations, IS 15652 Class B (11kV working voltage) or IEC 61111 Class 2 (17kV maximum use voltage) is the correct specification.
Yes. For underground mining environments, mats must be rated for the system voltage of the panel and moisture-resistant properties are strongly recommended. ASTM D178 Type II mats with ozone or moisture-resistant characteristics are preferred for permanently damp underground locations. Mats in underground areas should be inspected more frequently than those in surface installations.
Standard IS 15652 and IEC 61111 mats are designed for indoor use. For outdoor control rooms, surface switchyards and portable field maintenance in open-pit sites, ASTM D178 Type II mats with ozone or moisture-resistant properties should be specified. Portable roll-out formats in Class 0 or Class 1 are practical for field maintenance work.
Yes. IS 15652 certified mats align with Indian electrical safety requirements for mining facilities governed by the Directorate General of Mines Safety (DGMS) and the Mines Rules. Mats with valid type test certificates and BIS markings support compliance during DGMS inspections and third-party EHS audits. Always request a valid test certificate when procuring insulating mats for mining applications.