The challenge

Protect Personnel Working Around High-Voltage Electrical Equipment in Mining and Mineral Operations

Mining and mineral processing operations depend on continuous high-voltage electrical systems to power crushers, conveyors, ball mills, screening units, pumps and processing plants. Electrical workers and maintenance teams operate daily around 33kV/11kV substations, 6.6kV and 3.3kV motor control centres and 415V distribution boards across surface and underground sites. Even a small insulation failure in these environments can lead to severe electric shock, injury, fatality or a costly operational shutdown.

In mining operations, the electrical risk is very high because of heavy mineral dust, moisture from dewatering systems and underground conditions, intense floor vibration from heavy equipment and remote site locations where emergency response is slow. Electrical safety in this environment is not optional; it is critical to protect workers and maintain uninterrupted mining output.

Our electrical insulating rubber mats create a safe and compliant working zone around live electrical equipment, helping mining company EHS managers and maintenance teams protect personnel, reduce risk and meet stringent IS 15652 / IEC 61111 / ASTM D178 safety standards.

  1. 01 Electric shock risk near crushing plant panels, conveyor MCCs and 33kV/11kV substations
  2. 02 Mineral and coal dust accumulation on mat surfaces reducing insulation performance over time
  3. 03 Moisture and water ingress in underground electrical rooms and surface pump houses
  4. 04 Heavy vibration from crushers, mills and blasting activity accelerating mat wear
  5. 05 Strict DGMS, statutory and third-party audit requirements for certified electrical safety equipment

Trusted & Certified

Standards that stand behind every mat.

The Range

Four mats. One job — keep operators alive.

Deployment zones

Application of Electrical Insulating Mats in Mining and Mineral

Electrical insulating matting may be considered at work positions where personnel operate near electrical equipment. The correct specification depends on the task, equipment, standard and assessed hazard.

Discuss your site ↗
  • Transmission towers at sunset

    01Main Surface Substations

    • Substation equipment and pipework

      02Crushing and Screening Plant Panels

      • Aerial view of an outdoor solar and switchyard site

        03Underground Electrical Substations

        • Engineer reviewing panel drawings

          04Conveyor Drive MCC Rooms

          • Transmission towers at sunset

            05Mineral Processing Plant MCCs

            • Technician working on control equipment

              06Pump House and Dewatering Panels

              • Engineer viewing an electrical layout on screen

                07LT Distribution and Control Rooms

                • Solar panels under a cloudy sky

                  08Portable Field Maintenance Zones

                  Mining & Minerals facilities · Selection assistant

                  Find the right insulating mat class for your work area.

                  Choose the facility and system voltage to view a starting reference for your specification conversation. Always confirm the applicable standard and current test documents before procurement.

                  Insulating Mat Selector

                  Six questions · Standard, class and stock match

                  • IS 15652
                  • IEC 61111
                  • ASTM D178

                  Why Duratuf

                  Why Choose Duratuf for Insulating Rubber Matting in Mining & Minerals Industries

                  Use product documentation and a site-specific assessment to decide whether a particular Duratuf mat is right for the job.

                  Our Clients

                  We Are Proud To Work With

                  Our clients are not just business collaborations but relationships we value for a lifetime. We commit ourselves to manufacture features rich high quality insulating mats.

                  FAQs

                  Questions to settle before procurement.

                  Electrical safety mat selection is standards-led. The answers below are intentionally qualified; check current manufacturer documents and local requirements before specifying.

                  In mining industries, insulating mats should be installed in front of main surface substations (33kV/11kV), crushing and screening plant control panels, conveyor drive MCCs, mineral processing plant switchgear, underground electrical substations, pump house and dewatering panels and any control room where workers access live electrical equipment.

                  For 33kV main surface substations, IS 15652 Class C (33kV working voltage) or IEC 61111 Class 4 (36kV maximum use voltage) is required. For 11kV underground and surface substations, IS 15652 Class B (11kV working voltage) or IEC 61111 Class 2 (17kV maximum use voltage) is the correct specification.

                  Yes. For underground mining environments, mats must be rated for the system voltage of the panel and moisture-resistant properties are strongly recommended. ASTM D178 Type II mats with ozone or moisture-resistant characteristics are preferred for permanently damp underground locations. Mats in underground areas should be inspected more frequently than those in surface installations.

                  Standard IS 15652 and IEC 61111 mats are designed for indoor use. For outdoor control rooms, surface switchyards and portable field maintenance in open-pit sites, ASTM D178 Type II mats with ozone or moisture-resistant properties should be specified. Portable roll-out formats in Class 0 or Class 1 are practical for field maintenance work.

                  Yes. IS 15652 certified mats align with Indian electrical safety requirements for mining facilities governed by the Directorate General of Mines Safety (DGMS) and the Mines Rules. Mats with valid type test certificates and BIS markings support compliance during DGMS inspections and third-party EHS audits. Always request a valid test certificate when procuring insulating mats for mining applications.