IM Products in Nigeria2025-02-13T11:44:20+05:30

Quality-assured Insulating Mats in Nigeria: IEC 61111:2009, ASTM D-178 and IS 15652:2006

Leading Insulating Rubber Mat Company in Nigeria

Introduction to Duratuf Rubber Insulation Mat:

Duratuf offers high-quality insulating rubber mats in Nigeria. Their primary purpose is to protect people from electrical hazards. Duratuf’s electrical rubber mat has excellent insulating properties.
It has high dielectric strength and can withstand high voltages without breaking down. In addition, it comes with authentic test certificates and a warranty.
We offer IEC 61111:2009 compliant high voltage rubber mats, ASTM D-178 compliant electrical rubber mats, and IS 15652:2006 compliant insulated mats. They are extensively used in the power, manufacturing, automotive, and processing settings of Nigeria.

IEC 61111:2009 compliant insulating mats:
Our IEC 61111:2009 electrical rubber mat can be of Class 0, 1, 2, 3, and 4. Different classes of insulation mat are suitable for different applications. These mats can endure temperatures ranging from 1 kV to 36 kV.

ASTM D-178 compliant insulating mats:
Duratuf ASTM D-178 compliant insulated rubber mat can be of Classes 0 to 4. Class 0 is for working voltages up to 1 kV, Class 1 for 7.5 kV, Class 2 for 17 kV, Class 3 for 26.5 kV, and Class 4 is for working voltages up to 36 kV.
ASTM D-178 electrical insulation mats are further categorized into Type I and Type II. Type II is ozone, oil, and flame-resistant.

IS 15652:2006 compliant insulating mats:
Our IS 15652:2006 compliant electrical insulation rubber mat comes in Classes A, B, and C. The Class A electrical rubber mat is for working voltages up to 3.3 kV, Class B is for working voltages up to 11 kV, and Class C insulation mats are for working voltages up to 33 kV.

Check out these key features of our electrical insulation mats:

  • High dielectric strength: Our electrical rubber insulation mat can endure high voltages without breaking down.
  • Anti-slip: Our safety mats industrial have anti-slip properties. They have ribbed or dotted texture that prevents physical accidents.
  • Easy identification: Product labels help in the easy identification of the electrical mats.
  • Customization: Duratuf insulating mats are customization. You can tailor-make your mats according to your required dimensions and colors.

Reach out to our specialists if you have queries about our products.

Blog Image of IEC 61111
Second Blog Image of IEC 61111
Picture of Duratuf Electrical Rubber Mats IEC 61111

Certifications & Memberships

Want an Immediate Exclusive Quote?

Our team of specialists respond within 60 minutes!

Only takes a few seconds!

Technical Specification

Technical Specifications: IS 15652- X-Volt Insulating Mats

CharacteristicsValues
Material CompositionElastomer free from any insertion.
Tensile Strength (Min.)15N/mm2
Elongation at Break (Min.)250%
Leakage Current (Max.)10 mA
Insulation Resistance With
Water When Tested At 5000 V (Min.)
1,00,000 MΩ
Flame Retardance (Max.)Extinguishes Within 5 Secs
Aging Properties At 70 ± 1°C For 168 HoursT.S & E.B Not Less Than 75% Of Original Value
Acid, Alkali & Oil Resistance

T.S & E.B Not Less Than 80% Of Original Value
Working Temperature-10°C To 55°C
Tolerance Level±10% on thickness, ± 15 mm on width & length up to 600 mm and ± 20 mm for higher.

Technical Specifications: IEC 61111:2009 Insulating Mats

CharacteristicsValues
Material CompositionElastomer free from any insertion. Typically, a combination of natural rubber and other synthetic polymers.
Mechanical Puncture Resistance (min)
70 N
Slip Resistance (min)50 N
Ageing Properties at 70±2°C for 168 hoursMechanical Puncture Resistance not less than 80% of original value
Flame RetardanceDoes not catch fire
Low Temperature Test at - 25±3°CNo visible tear, cracks or breaks
Acid ResistanceMechanical Test Values not less than 75% of original value
Oil ResistanceMechanical Test Values not less than 75% of original value
Working Temperature-25°C to 55°C
Tolerance Limit:± 10% on thickness, ± 2% on length & width

Technical Specifications: ASTM D178 Insulating Mats

CharacteristicsValues
Material CompositionElastomer free from any insertion.
Tensile Strength (Min.)15N/mm2
Elongation at Break (Min.)250%
Leakage Current (Max.)10 mA
Insulation Resistance With
Water When Tested At 5000 V (Min.)
1,00,000 MΩ
Flame Retardance (Max.)Extinguishes Within 5 Secs
Aging Properties At 70 ± 1°C For 168 HoursT.S & E.B Not Less Than 75% Of Original Value
Acid, Alkali & Oil Resistance

T.S & E.B Not Less Than 80% Of Original Value
Working Temperature-10°C To 55°C
Tolerance Level±10% on thickness, ± 15 mm on width & length up to 600 mm and ± 20 mm for higher.
0+
Years in Business
0+
Country’s Exported
0+
Happy Clients
0+
Successful Projects

Duratuf Electrical Insulating Rubber Mats: More Details

Applications of the Duratuf High-voltage Rubber Mats

  • Data Centers (UPS Rooms, Telecommunication Rooms, Generator Rooms etc)
  • Electrical Laboratories (Circuit Testing Zones, Equipment Testing Zones etc)
  • High Voltage Rooms (Testing Labs, Switchgear Room, Control Rooms etc)
  • Battery Rooms (Battery Storage Racks, Battery Charging Stations etc)
  • Control Panels (Electrical Cabinets, Variable Frequency Drives (VFD) Cabinets etc)
  • Transformer Stations (Cable Trenches, Busbar Areas, Switching Areas etc)
  • Switchgear Rooms (Distribution Boards, Circuit Breaker Panels etc)
  • Railway Electrification Systems (Signal Equipment Rooms, Overhead Equipment (OHE) Maintenance Depots etc)
  • Electrical Substations (Substation Control Rooms, Switchyards etc)
  • Power Plants (Generator and Turbine Areas, Transformer Yards etc)

Exclusive Features Of Duratuf Electrical Insulation Mats

Icon of 100% Shock Proof protection
High Di-electric Strength
Icon of ERDA Test Certification
Quality-Certified
Icon of Safety Audit Compliant
Safety-Audit Passed
Icon of Chemical & Flame Retardant
Chemical, UV, Ozone and Flame Retardant
Icon of Moisture & Ozone Resistant
Moisture and Water Resistant
Icon of Ready-Stock Inventory
Up to 10,000 sq m Ready Stock
Icon of Expert Consultation
Free Expert Guidance
Icon of Competitive Pricing
Competitive Pricing
Icon of Proactive Customer Support
End-to-End Customer Support

FAQs: Electrical Rubber Mat

When you work around high voltage equipment, you might get an electric shock from a loose or damaged wire. Electric shocks can be deadly. Not only can they hurt the workers, but the accident can also disturb the flow of work.
Here, an electrical mat works as a protective cover and reduces the intensity of damage. If a worker standing on them gets exposed to high voltage, these rubber mats will channel the static electricity to the ground instead of making it pass through the human body.
Yes, Duratuf electrical switchboard matting complies with the OSHA (Occupational Safety and Health Administration) guidelines. In addition, they also adhere to the HSE (Health, Safety, and Environment) regulations. They meet the industrial safety standards.
The order processing time is influenced by the product and the quantity that you want to purchase. For 0-300 sq. meters, it takes 3-4 weeks. Whereas, for 300-700 sq. meters, it takes 4-6 weeks. On the other hand, beyond that, the order processing time is 6-8 weeks.
Yes, we offer discounts if you purchase insulating mats in bulk. You will get this discount if you get the minimum order quantity of 300 sq. meters of electrical mats. You can reach out to us to know about more details.

Customer Reviews

Excellent products with Exception Service from Mr.Tapabrata !!!

July 18, 2022

We have had some inquiries for Electrical Mats and they have given us good response to it. Their quality is at par with the European and American products and would definitely recommend it.

Juzar

Good Customer support and Product.

July 18, 2022

We purchased Electrical Insulation Rubber mats for our Project in Doha. Had a good Experience with Mr. Tapabrata who supported till delivery. We can say with confidence that this mat is good and durable. Recommended!

Karthik Raj

Planning to Resell Duratuf Electrical Mats?

Check out the full list of your benefits now!

Our Clientele

Are you paying a higher insulating mat price?

Know the current price of electrical rubber mats in the market

ELECTRICAL SAFETY BLOGS

Go to Top