Electrical Rubber Mat in Ahmedabad, Gujarat
Buy IS 15652:2006 type-tested, ISI-marked Duratuf electrical insulating mats for substations, panels, control rooms and other installations across Gujarat from Duratuf, a trusted supplier
Duratuf XVolt Electrical Rubber Mat
In Ahmedabad, Vatva GIDC concentrates chemicals, dyestuffs, pharmaceuticals and engineering manufacturing across more than 500 hectares and 2,500 units. Naroda adds a foundry, engineering, textile machinery and pharmaceutical cluster to the city’s established manufacturing belt. Odhav and Kathwada form the engineering backbone along the SP Ring Road corridor, running fabrication, plastics and MSME manufacturing operations. Sanand has emerged as a major automotive and EV manufacturing destination, with pharmaceutical, electronics and plastics companies also active across the zone. Changodar and Bavla on the Rajkot highway approach handle logistics, warehousing and mid-size manufacturing. GIFT City with data centre campuses and financial services facilities. Every one of these zones has electrical workers operating near live panels, switchgear and transformer equipment through every shift.
Duratuf’s XVolt electrical rubber mat is built to keep operators safe from shock while they work. Our insulating mat is manufactured and type-tested to IS 15652:2006, ISI marked under BIS approval and available in Class A, B and C offering safety up to 36 kV so it matches whatever voltage you are dealing with from a control panel to a full substation. We offer timely and secure delivery across Gujarat from our Bhiwadi warehouse and custom sizes are also available if your site needs something different from our standard mats.
Key Features of Electrical Insulating Mats – IS 15652
Every electrical mat we dispatch to Ahmedabad is type-tested to IS 15652:2006 before it leaves our Bhiwadi warehouse. Whether it is for a chemical plant switchgear room in Vatva, an MCC panel inside a Sanand automotive facility, an engineering unit in Naroda or an electrical room in a GIFT City data centre campus, here is what actually determines whether a mat passes inspection and holds up in service.
ISI Marked
Type tested to IS 15652:2006, ISI Marked approved by BIS
Class A, B & C Ratings
Working voltages of 3.3 kV, 11 kV and 33 kV to match your installation
High Dielectric Strength
Offers exceptional dielectric performance for maximum protection against electrical shock.
Anti-Skid Surface
Engineered with a dotted anti-slip top and textured anti-skid bottom for enhance safety & stability
Wide Temperature Range
Performs reliably from -10°C to +55°C
Standard Sizes and Asthetic Colors
All standard sizes are available as per IS 15652:2006 along with asthetic colors (Black, Blue & Red)
Compliance and Standards
In Gujarat, electrical safety matting comes under the Chief Electrical Inspector to the Government of Gujarat, a statutory authority under the state’s Energy and Petrochemicals Department. The IS 15652:2006 compliance requirement for switchgear rooms, transformer bays and panel areas is enforced by the Electrical Inspectorate during mandatory audits of HT-connected facilities across all of these zones, regardless of which utility supplies the power. Duratuf’s electrical mats are manufactured and type-tested to IS 15652:2006 and carry the ISI mark with BIS approval, which is what inspection officers look for during those checks.
IS 15652 Electrical Insulating Mats Classes and Voltage Rating
| Class | Thickness | Working Voltage | AC Proof Voltage | Dielectric Strength |
|---|---|---|---|---|
| A | 2.0 mm | 3.3 kV | 10.0 kV | 30.0 kV |
| B | 2.5 mm | 11.0 kV | 22.0 kV | 45.0 kV |
| C | 3.0 mm | 33.0 kV | 36.0 kV | 65.0 kV |
Also available with Auto-Glow Safety Border featuring a 2" auto-glow strip and 3" high-visibility yellow safety strip along both edges accross the length, clearly defining the safe working area during normal operation and maintaining boundary visibility during power outages or low-light conditions.
IS 15652 Electrical Mat Technical Specification
| Characteristics | Values |
|---|---|
| Material Composition | Elastomer free from any insertion. Typically, a combination of PVC and synthetic rubber polymers. |
| Antiskid Design | Dotted Design |
| Tensile Strength (T.S.) | 15 N/mm² (min.) |
| Elongation at Break (E.B.) | 250% (min.) |
| Leakage Current | 10 mA (max.) |
| Insulation Resistance with Water when tested at 500 V | 1,00,000 MΩ (min.) |
| Flame Retardant | Extinguishes within 5 secs (max.) |
| Ageing Properties at 70±1°C for 168 hours | T.S. & E.B. not less than 75% of original value |
| Acid, Alkali & Oil Resistance | T.S. & E.B. not less than 80% of original value |
| Working Temperature | -10°C to 55°C |
| Standard Size | 1.0 Mtr. Wide x 10.0 Mtr. Long for all classes |
| Custom Size | 1.0 Mtr. Wide x Length as per Customer's Requirement up to 30mtr. Long. |
| Standard Colour | Black, Blue & Red without Metallic Derivatives. |
Cut lengths, custom shapes, and colours are available upon request.
Note: Manufacturing tolerance of ±10% on thickness, ±15mm on width & length up to 600mm and ±20mm for higher.
Application of Electrical Rubber Mats in Ahmedabad, Gujarat
The insulating mats are used in electrical installations where operators work near live electric devices and the risk of electrical hazards is high. Ahmedabad’s industries use a wide range of electrical equipment with varying voltage classes and compliance requirements. Here is where Duratuf XVolt insulating mats get deployed across the city.
- Electrical Substations
- HT/LT Control Panel Flooring
- Switchboard & Switchgear Rooms
- Transformer Rooms
- Generator & Lift Rooms
- Bus Bar Areas
- Live Equipment Work Areas
- MCC Rooms
- Relay & Metering Rooms
- Distribution Transformer Platforms
- Cable Junction & Joint Areas
- Electrical Maintenance & Testing Bays
Working in any of these areas?
Get the right mat class for your voltage requirement.
Why Choose Duratuf for Insulating Rubber Matting in Ahmedabad
At Duratuf, we help industries operate more safely and effectively through complaints, technology-driven safety solutions. we Believe that earning a living should never cost a life.
Years of Industrial Safety Expetise
With 16+ years in the business and 4,142+ happy customers across 65+ countries, our insulating mats are already at work.
ISI Marked Manufacturing
Every XVolt mat is manufactured and type-tested to IS 15652:2006, so you get ISI marked matting built to India's electrical safety standard.
Global distribution network
A network of trusted channel partners ensures fast dispatch and reliable delivery, getting the right safety equipment to your site on time.
Brand Reputation
Highly satisfied & loyal clientele base with years of repeat orders
What Our Clients Say
"The team has been very responsive and prompt by sharing the required information on the products as well as channel partners"
"Good experience with Duratuf and good insulating mat as well"
"As an authorized dealer for the Gujarat region, we have had an exceptional experience working with Team Duratuf. Their staff is incredibly polite, highly supportive, and always ready to assist with any queries. The ordering and delivery processes are consistently quick and entirely hassle-free."
"We are satisfied with the excellent product quality, reliable services, and consistent supply."
"Quality product and good service"
"I would like to appreciate the excellent support and professional coordination from your side. Your prompt response and helpful approach are truly commendable."
"Good service and polite staff, very satisfied with the service."
"We received the quotation for the rubber mat very promptly, which reflects excellent responsiveness and professionalism. The quick turnaround helped us proceed with our evaluation without delay."
"Your service is good and we have received your product and your follow up is also good."
Frequently Asked Questions
Does IS 15652 apply to data centre and financial services electrical rooms in GIFT City?
Yes. IS 15652:2006 applies to any electrical installation where an operator works near live switchgear, UPS panels, distribution boards or generator rooms, regardless of sector. GIFT City's data centre campuses and financial services buildings run the same LT and HT electrical infrastructure as any industrial facility, and the compliance requirement for matting in those panel areas is identical.
Our Vatva facility has both an LT main panel and an HT receiving station. Do we need different mat classes for each area?
Yes. The class is determined by the system voltage in each specific area, not the facility as a whole. Your LT main panel area needs Class A matting (3.3 kV working voltage). Your HT receiving station needs Class B at 11 kV or Class C at 33 kV depending on the system voltage in that area. Each room with live equipment needs its own correctly rated mat.
Our Vatva GIDC unit has been operational since the 1970s. Do older industrial installations still have to meet IS 15652 compliance?
Yes. The IS 15652:2006 obligation applies to any active electrical installation regardless of when the building was constructed. Gujarat's Electrical Inspectorate does not exempt older GIDC units from compliance during mandatory periodic inspections. Older Vatva and Naroda facilities are frequently flagged during audits precisely because safety equipment from decades ago is rarely still compliant.