Electrical Rubber Mat in Pune, Maharashtra
Buy IS 15652:2006 type-tested, ISI-marked Duratuf XVolt mats for substations, panels, control rooms, switchboard and more across Maharashtra from a trusted supplier
Duratuf XVolt Electrical Rubber Mat
Electricians and plant operators across Pune work near live switchboards, substations, transformer panels and electrical boards every day, from the Pimpri-Chinchwad and Bhosari industrial estates to the automotive assembly lines in Chakan and the large-scale manufacturing units spread across Ranjangaon and Talegaon along the Pune-Nashik corridor. A moment of contact with a live panel can mean a serious shock and electrical hazard, so the mat someone stands on matters just as much as the gloves on their hands or the training they have had before they ever step near a panel, a switchboard or a control room.
Duratuf’s XVolt electrical rubber mat is built to mitigate that gap and keep operators safe from shock while they work. Our electrical insulating mat is manufactured and type-tested to IS 15652:2006, ISI marked approved by BIS and available in Class A, B and C offering safety up to 36 kV so it matches whatever voltage you are dealing with from a control panel to a full substation. We offer timely and secure delivery across Maharashtra from our Bhiwadi warehouse and custom sizes are also available if your site needs something different from our standard mats.
Key Features of Electrical Insulating Mats – IS 15652
All the electrical mats we dispatch to Pune are type-tested to IS 15652:2006 before they leave our Bhiwadi warehouse. If you are specifying matting for a substation, a switchgear room or one of Pune’s engineering and manufacturing facilities, here is what actually determines whether a mat passes inspection and lasts.
ISI Marked
Type tested to IS 15652:2006, ISI Marked approved by BIS
Class A, B & C Ratings
Working voltages of 3.3 kV, 11 kV and 33 kV to match your installation
High Dielectric Strength
Offers exceptional dielectric performance for maximum protection against electrical shock.
Anti-Skid Surface
Engineered with a dotted anti-slip top and textured anti-skid bottom for enhance safety & stability
Wide Temperature Range
Performs reliably from -10°C to +55°C
Standard Sizes and Asthetic Colors
All standard sizes are available as per IS 15652:2006 along with asthetic colors (Black, Blue & Red)
Compliance and Standards
In Maharashtra, electrical safety matting comes under the Chief Electrical Inspector to the Government of Maharashtra, a statutory authority under the state’s Energy Department with Pune covered by its Pune Zone office. Duratuf’s XVolt electrical insulating mats are manufactured and type-tested to IS 15652:2006 and carry the ISI mark with BIS approval, which is what is required for switchboard and generator rooms, distribution units, control panels, substation flooring and other electrical installations under that inspectorate.
IS 15652 Electrical Insulating Mats Classes and Voltage Rating
| Class | Thickness | Working Voltage | AC Proof Voltage | Dielectric Strength |
|---|---|---|---|---|
| A | 2.0 mm | 3.3 kV | 10.0 kV | 30.0 kV |
| B | 2.5 mm | 11.0 kV | 22.0 kV | 45.0 kV |
| C | 3.0 mm | 33.0 kV | 36.0 kV | 65.0 kV |
Also available with Auto-Glow Safety Border featuring a 2" auto-glow strip and 3" high-visibility yellow safety strip along both edges accross the length, clearly defining the safe working area during normal operation and maintaining boundary visibility during power outages or low-light conditions.
IS 15652 Electrical Mat Technical Specification
| Characteristics | Values |
|---|---|
| Material Composition | Elastomer free from any insertion. Typically, a combination of PVC and synthetic rubber polymers. |
| Antiskid Design | Dotted Design |
| Tensile Strength (T.S.) | 15 N/mm² (min.) |
| Elongation at Break (E.B.) | 250% (min.) |
| Leakage Current | 10 mA (max.) |
| Insulation Resistance with Water when tested at 500 V | 1,00,000 MΩ (min.) |
| Flame Retardant | Extinguishes within 5 secs (max.) |
| Ageing Properties at 70±1°C for 168 hours | T.S. & E.B. not less than 75% of original value |
| Acid, Alkali & Oil Resistance | T.S. & E.B. not less than 80% of original value |
| Working Temperature | -10°C to 55°C |
| Standard Size | 1.0 Mtr. Wide x 10.0 Mtr. Long for all classes |
| Custom Size | 1.0 Mtr. Wide x Length as per Customer's Requirement up to 30mtr. Long. |
| Standard Colour | Black, Blue & Red without Metallic Derivatives. |
Cut lengths, custom shapes, and colours are available upon request.
Note: Manufacturing tolerance of ±10% on thickness, ±15mm on width & length up to 600mm and ±20mm for higher.
Application of Electrical Rubber Mats in Pune, Maharashtra
The insulating mats are used in electrical installations where operators deal with live electric devices and the chance of electrical hazards is high. Here is where Duratuf XVolt mats get used across Pune’s manufacturing, automotive, IT and infrastructure sites, from PCMC and Chakan’s OEM plants to Hadapsar’s engineering facilities, and the class you would pick for each
- Electrical Substations
- HT/LT Control Panel Flooring
- Switchboard & Switchgear Rooms
- Transformer Rooms
- Generator & Lift Rooms
- Bus Bar Areas
- Live Equipment Work Areas
- MCC Rooms
- Relay & Metering Rooms
- Distribution Transformer Platforms
- Cable Junction & Joint Areas
- Electrical Maintenance & Testing Bays
Working in any of these areas?
Get the right mat class for your voltage requirement.
Why Choose Duratuf for Insulating Rubber Matting in Pune
At Duratuf, we help industries operate more safely and effectively through complaints, technology-driven safety solutions. we Believe that earning a living should never cost a life.
Years of Industrial Safety Expetise
With 16+ years in the business and 4,142+ happy customers across 65+ countries, our insulating mats are already at work.
ISI Marked Manufacturing
Every XVolt mat is manufactured and type-tested to IS 15652:2006, so you get ISI marked matting built to India's electrical safety standard.
Global distribution network
Our Bhiwadi warehouse ensures fast dispatch to Pune, Pimpri-Chinchwad, Chakan and all major industrial zones across Maharashtra, getting the right safety equipment to your site on time.
Brand Reputation
A growing and highly satisfied client base across Maharashtra's Industrial sectors, with years of repeat orders reflecting consistent product quality.
What Our Clients Say
"The team has been very responsive and prompt by sharing the required information on the products as well as channel partners"
"Good experience with Duratuf and good insulating mat as well"
"As an authorized dealer for the Gujarat region, we have had an exceptional experience working with Team Duratuf. Their staff is incredibly polite, highly supportive, and always ready to assist with any queries. The ordering and delivery processes are consistently quick and entirely hassle-free."
"We are satisfied with the excellent product quality, reliable services, and consistent supply."
"Quality product and good service"
"I would like to appreciate the excellent support and professional coordination from your side. Your prompt response and helpful approach are truly commendable."
"Good service and polite staff, very satisfied with the service."
"We received the quotation for the rubber mat very promptly, which reflects excellent responsiveness and professionalism. The quick turnaround helped us proceed with our evaluation without delay."
"Your service is good and we have received your product and your follow up is also good."
Frequently Asked Questions
Does Maharashtra's electrical safety framework require IS 15652 certified mats for industrial facilities?
Yes. es. The Chief Electrical Inspector to the Government of Maharashtra enforces compliance under the Indian Electricity Rules and Indian Standards for electrical safety equipment. For switchboard rooms, generator rooms, distribution panels and substation flooring subject to periodic inspection in the Pune Zone, IS 15652:2006 certified matting is the recognised benchmark.
Which XVolt class do Pune's Chakan and PCMC industrial plants typically specify?
Most 11 kV switchgear rooms in Pimpri-Chinchwad and Chakan automotive plants specify Class B with 2.5 mm, 11 kV working voltage, 22 kV AC proof voltage. Facilities running 33 kV equipment, common in large OEM transformer yards and Ranjangaon industrial substations, need Class C.
Can Duratuf supply cut-to-length mats for non-standard bay dimensions in Pune's older plants?
Yes. Standard IS 15652 rolls are 1.0 m wide and available in multiple lengths. We also supply custom lengths from our Bhiwadi facility, which is a regular requirement for Pune's older Bhosari and Hadapsar plants where switchgear bays were built to non-standard dimensions.






