Electrical Rubber Mat in Surat, Gujarat
Buy IS 15652:2006 type-tested, ISI-marked Duratuf XVolt electrical insulating mats for substations, panels, control rooms and other electric installations across Gujarat from Duratuf, a trusted supplier
Duratuf XVolt Electrical Rubber Mat
Surat’s industries covers some of India’s most concentrated manufacturing activity. At Hazira on the western edge, a deep-sea port and heavy industrial corridor runs petrochemical plants, fertilizer units, LNG processing facilities and port operations around the clock. Across the city, Sachin GIDC, Pandesara, Udhna, Katargam and Ichhapore form the core of Surat’s textile and engineering belt, running synthetic fabric weaving, dyeing and finishing, diamond cutting and polishing, chemicals and plastics manufacturing through continuous multi-shift production. Further along the NH-48 corridor, Kadodara, Palsana and Olpad extend the industrial spread with fabric processing, engineering workshops and warehousing operations. Across all of these zones, electrical workers deal with live switchgear, control panels and transformer equipment as a routine part of every shift.
Duratuf’s XVolt electrical rubber mat is built to keep operators safe from shock while they work with this live electrical equipment. Our insulating mats are manufactured and type-tested to IS 15652:2006, ISI marked under BIS approval and available in Class A, B and C offering safety up to 36 kV so it matches whatever voltage you are dealing with from a control panel to a full substation. We offer timely and secure delivery across Gujarat from our Bhiwadi warehouse and custom sizes are also available if your site needs something different from our standard mats.
Key Features of Electrical Insulating Mats – IS 15652
Every electrical mat we dispatch to Surat is type-tested to IS 15652:2006 before it leaves our Bhiwadi warehouse. Whether the requirement is for a switchgear room at a Hazira petrochemical facility, an MCC panel inside a Sachin GIDC manufacturing unit or a main distribution board in a Pandesara or Palsana textile plant, here is what actually determines whether a mat passes inspection and holds up in service.
ISI Marked
Type tested to IS 15652:2006, ISI Marked approved by BIS
Class A, B & C Ratings
Working voltages of 3.3 kV, 11 kV and 33 kV to match your installation
High Dielectric Strength
Offers exceptional dielectric performance for maximum protection against electrical shock.
Anti-Skid Surface
Engineered with a dotted anti-slip top and textured anti-skid bottom for enhance safety & stability
Wide Temperature Range
Performs reliably from -10°C to +55°C
Standard Sizes and Asthetic Colors
All standard sizes are available as per IS 15652:2006 along with asthetic colors (Black, Blue & Red)
Compliance and Standards
In Gujarat, electrical safety matting comes under the Chief Electrical Inspector to the Government of Gujarat, a statutory authority under the state’s Energy and Petrochemicals Department. Surat’s power distribution is managed by two licensed utilities but the IS 15652:2006 compliance requirement for switchgear rooms, transformer bays, panel areas and other installations is enforced by the Electrical Inspectorate during mandatory facility audits, regardless of which utility supplies the power. Duratuf’s XVolt insulating mats are manufactured and type-tested to IS 15652:2006 and carry the ISI mark with BIS approval, which is what inspection officers look for during those inspections.
IS 15652 Electrical Insulating Mats Classes and Voltage Rating
| Class | Thickness | Working Voltage | AC Proof Voltage | Dielectric Strength |
|---|---|---|---|---|
| A | 2.0 mm | 3.3 kV | 10.0 kV | 30.0 kV |
| B | 2.5 mm | 11.0 kV | 22.0 kV | 45.0 kV |
| C | 3.0 mm | 33.0 kV | 36.0 kV | 65.0 kV |
Also available with Auto-Glow Safety Border featuring a 2" auto-glow strip and 3" high-visibility yellow safety strip along both edges accross the length, clearly defining the safe working area during normal operation and maintaining boundary visibility during power outages or low-light conditions.
IS 15652 Electrical Mat Technical Specification
| Characteristics | Values |
|---|---|
| Material Composition | Elastomer free from any insertion. Typically, a combination of PVC and synthetic rubber polymers. |
| Antiskid Design | Dotted Design |
| Tensile Strength (T.S.) | 15 N/mm² (min.) |
| Elongation at Break (E.B.) | 250% (min.) |
| Leakage Current | 10 mA (max.) |
| Insulation Resistance with Water when tested at 500 V | 1,00,000 MΩ (min.) |
| Flame Retardant | Extinguishes within 5 secs (max.) |
| Ageing Properties at 70±1°C for 168 hours | T.S. & E.B. not less than 75% of original value |
| Acid, Alkali & Oil Resistance | T.S. & E.B. not less than 80% of original value |
| Working Temperature | -10°C to 55°C |
| Standard Size | 1.0 Mtr. Wide x 10.0 Mtr. Long for all classes |
| Custom Size | 1.0 Mtr. Wide x Length as per Customer's Requirement up to 30mtr. Long. |
| Standard Colour | Black, Blue & Red without Metallic Derivatives. |
Cut lengths, custom shapes, and colours are available upon request.
Note: Manufacturing tolerance of ±10% on thickness, ±15mm on width & length up to 600mm and ±20mm for higher.
Application of Electrical Rubber Mats in Surat, Gujarat
The insulating mats are used in electrical installations where operators work near live electric devices and the risk of electrical hazards is high. Surat’s industrial zones cover a wide range of electrical equipment, each with its own voltage class and compliance requirement. Here is where Duratuf XVolt electrical mats get deployed across the city’s industrial sites.
- Electrical Substations
- HT/LT Control Panel Flooring
- Switchboard & Switchgear Rooms
- Transformer Rooms
- Generator & Lift Rooms
- Bus Bar Areas
- Live Equipment Work Areas
- MCC Rooms
- Relay & Metering Rooms
- Distribution Transformer Platforms
- Cable Junction & Joint Areas
- Electrical Maintenance & Testing Bays
Working in any of these areas?
Get the right mat class for your voltage requirement.
Why Choose Duratuf for Insulating Rubber Matting in Surat
At Duratuf, we help industries operate more safely and effectively through complaints, technology-driven safety solutions. we Believe that earning a living should never cost a life.
Years of Industrial Safety Expetise
With 16+ years in the business and 4,142+ happy customers across 65+ countries, our insulating mats are already at work.
ISI Marked Manufacturing
Every XVolt mat is manufactured and type-tested to IS 15652:2006, so you get ISI marked matting built to India's electrical safety standard.
Global distribution network
We dispatch to Surat from our Bhiwadi warehouse through a reliable logistics network, ensuring our electrical mats reach your site safely and on scheduled time.
Brand Reputation
Highly satisfied & loyal clientele base with years of repeat orders
What Our Clients Say
"The team has been very responsive and prompt by sharing the required information on the products as well as channel partners"
"Good experience with Duratuf and good insulating mat as well"
"As an authorized dealer for the Gujarat region, we have had an exceptional experience working with Team Duratuf. Their staff is incredibly polite, highly supportive, and always ready to assist with any queries. The ordering and delivery processes are consistently quick and entirely hassle-free."
"We are satisfied with the excellent product quality, reliable services, and consistent supply."
"Quality product and good service"
"I would like to appreciate the excellent support and professional coordination from your side. Your prompt response and helpful approach are truly commendable."
"Good service and polite staff, very satisfied with the service."
"We received the quotation for the rubber mat very promptly, which reflects excellent responsiveness and professionalism. The quick turnaround helped us proceed with our evaluation without delay."
"Your service is good and we have received your product and your follow up is also good."
Frequently Asked Questions
Do smaller LT-connected textile and diamond processing units in Surat also need IS 15652 mats?
Yes. The IS 15652 requirement applies to any electrical installation where an operator works near live switchgear, a panel board or a distribution board, regardless of whether the facility runs on an HT or LT connection. For most of Surat's textile weaving and diamond processing units, Class A (3.3 kV working voltage) covers the LT switchgear and main panel areas where the mat needs to be placed.
Surat has both Torrent Power and DGVCL. Does the IS 15652 compliance authority differ between zones?
No. The distribution licensee, whether Torrent Power or DGVCL, handles power supply and metering. The IS 15652 compliance requirement inside an electrical installation is enforced by the Chief Electrical Inspector to the Government of Gujarat during periodic audits. Both distribution zones fall under the same Inspectorate, so the compliance obligation is identical for all facilities.
We supply electrical safety equipment to multiple industrial units across Surat's GIDC estates. Can a single order cover all sites?
Yes. We handle consolidated orders for EHS contractors and safety procurement teams covering multiple units across Sachin GIDC, Pandesara, Kadodara, Palsana and Udhna. Each site's class and quantity can be specified separately in one purchase order, with delivery addressed to individual units or a central warehouse.






