Electrical Rubber Mat in Bengaluru, Karnataka
Buy IS 15652:2006 type-tested, ISI-marked Duratuf XVolt electrical insulating mats for substations, panels, control rooms and other electrical installations across Karnataka from Duratuf, a trusted supplier
Duratuf XVolt Electrical Rubber Mat
Bengaluru runs two distinct categories of electrical installation simultaneously. In Peenya, Jigani, Bommasandra and Doddaballapur, manufacturing units, auto ancillary plants and engineering workshops operate industrial switchgear and MCC rooms through continuous shifts. In Whitefield, Electronics City and the HAL-ISRO-BEL facility corridor, aerospace, defense and public sector installations manage high-voltage systems where a single compliance gap carries both safety and regulatory consequences. Both categories need the same thing on the floor: a mat that is genuinely IS 15652:2006 certified, not just labelled.
Duratuf’s XVolt electrical rubber mats are is manufactured and type-tested to IS 15652:2006, ISI marked with BIS approval and available in Class A, B and C offering safety up to 36 kV so it matches whatever voltage you are dealing with from a control panel to a full substation. We offer timely and secure delivery across Karnataka from our Bhiwadi warehouse and custom sizes are also available if your site needs something different from our standard mats.
Key Features of Electrical Insulating Mats – IS 15652
Every XVolt mat dispatched to Bengaluru is type-tested to IS 15652:2006 before it leaves our Bhiwadi warehouse. Whether the requirement is for a Peenya manufacturing plant, a switchgear room in an Electronics City data centre or a substation inside a PSU campus, here is what actually determines whether a mat passes inspection and holds up in service.
ISI Marked
Type tested to IS 15652:2006, ISI Marked approved by BIS
Class A, B & C Ratings
Working voltages of 3.3 kV, 11 kV and 33 kV to match your installation
High Dielectric Strength
Offers exceptional dielectric performance for maximum protection against electrical shock.
Anti-Skid Surface
Engineered with a dotted anti-slip top and textured anti-skid bottom for enhance safety & stability
Wide Temperature Range
Performs reliably from -10°C to +55°C
Standard Sizes and Asthetic Colors
All standard sizes are available as per IS 15652:2006 along with asthetic colors (Black, Blue & Red)
Compliance and Standards
In Karnataka, electrical safety matting falls under the Chief Electrical Inspector to the Government of Karnataka, a statutory authority under the state’s Energy Department. Bengaluru, as the state capital, is also home to the inspectorate’s head office, which means facilities here, from BESCOM-connected industrial substations to PSU campuses with dedicated power supply arrangements, are subject to direct scrutiny from the primary circle. Duratuf’s XVolt electrical mats are manufactured and type-tested to IS 15652:2006 and carry the ISI mark with BIS approval, which is what is required for switchboard and transformer rooms, distribution units, control panels, substation flooring and other electrical installations under that jurisdiction.
IS 15652 Electrical Insulating Mats Classes and Voltage Rating
| Class | Thickness | Working Voltage | AC Proof Voltage | Dielectric Strength |
|---|---|---|---|---|
| A | 2.0 mm | 3.3 kV | 10.0 kV | 30.0 kV |
| B | 2.5 mm | 11.0 kV | 22.0 kV | 45.0 kV |
| C | 3.0 mm | 33.0 kV | 36.0 kV | 65.0 kV |
Also available with Auto-Glow Safety Border featuring a 2" auto-glow strip and 3" high-visibility yellow safety strip along both edges accross the length, clearly defining the safe working area during normal operation and maintaining boundary visibility during power outages or low-light conditions.
IS 15652 Electrical Mat Technical Specification
| Characteristics | Values |
|---|---|
| Material Composition | Elastomer free from any insertion. Typically, a combination of PVC and synthetic rubber polymers. |
| Antiskid Design | Dotted Design |
| Tensile Strength (T.S.) | 15 N/mm² (min.) |
| Elongation at Break (E.B.) | 250% (min.) |
| Leakage Current | 10 mA (max.) |
| Insulation Resistance with Water when tested at 500 V | 1,00,000 MΩ (min.) |
| Flame Retardant | Extinguishes within 5 secs (max.) |
| Ageing Properties at 70±1°C for 168 hours | T.S. & E.B. not less than 75% of original value |
| Acid, Alkali & Oil Resistance | T.S. & E.B. not less than 80% of original value |
| Working Temperature | -10°C to 55°C |
| Standard Size | 1.0 Mtr. Wide x 10.0 Mtr. Long for all classes |
| Custom Size | 1.0 Mtr. Wide x Length as per Customer's Requirement up to 30mtr. Long. |
| Standard Colour | Black, Blue & Red without Metallic Derivatives. |
Cut lengths, custom shapes, and colours are available upon request.
Note: Manufacturing tolerance of ±10% on thickness, ±15mm on width & length up to 600mm and ±20mm for higher.
Application of Electrical Rubber Mats in Bengaluru, Karnataka
The insulating mats are used in electrical installations where operators deal with live electric devices and the chance of electrical hazards is high. Bengaluru’s industrial spread over Peenya, Rajajinagar, Jigani, Bommasandra, Bidadi and Hoskote on the manufacturing side, and Whitefield, Electronics City and Hebbal on the technology, and PSU sides and covers a wide range of voltage ranges and compliance requirements. Here is where Duratuf XVolt electrical mats can be used across this sites.
- Electrical Substations
- HT/LT Control Panel Flooring
- Switchboard & Switchgear Rooms
- Transformer Rooms
- Generator & Lift Rooms
- Bus Bar Areas
- Live Equipment Work Areas
- MCC Rooms
- Relay & Metering Rooms
- Distribution Transformer Platforms
- Cable Junction & Joint Areas
- Electrical Maintenance & Testing Bays
Working in any of these areas?
Get the right mat class for your voltage requirement.
Why Choose Duratuf for Insulating Rubber Matting in Bengaluru
At Duratuf, we help industries operate more safely and effectively through complaints, technology-driven safety solutions. we Believe that earning a living should never cost a life.
Years of Industrial Safety Expetise
With 16+ years in the business and 4,142+ happy customers across 65+ countries, our insulating mats are already at work.
ISI Marked Manufacturing
Every XVolt mat is manufactured and type-tested to IS 15652:2006, so you get ISI marked matting built to India's electrical safety standard.
Global distribution network
We dispatch to Bengaluru from our Bhiwadi warehouse through a reliable logistics network, ensuring XVolt mats reach Peenya, Jigani, Electronics City and other industrial clusters without delay.
Brand Reputation
A growing client base across Bengaluru's key industrial sectors, with repeat orders from procurement teams who need consistency above everything.
What Our Clients Say
"The team has been very responsive and prompt by sharing the required information on the products as well as channel partners"
"Good experience with Duratuf and good insulating mat as well"
"As an authorized dealer for the Gujarat region, we have had an exceptional experience working with Team Duratuf. Their staff is incredibly polite, highly supportive, and always ready to assist with any queries. The ordering and delivery processes are consistently quick and entirely hassle-free."
"We are satisfied with the excellent product quality, reliable services, and consistent supply."
"Quality product and good service"
"I would like to appreciate the excellent support and professional coordination from your side. Your prompt response and helpful approach are truly commendable."
"Good service and polite staff, very satisfied with the service."
"We received the quotation for the rubber mat very promptly, which reflects excellent responsiveness and professionalism. The quick turnaround helped us proceed with our evaluation without delay."
"Your service is good and we have received your product and your follow up is also good."
Frequently Asked Questions
Is IS 15652 certification mandatory for switchgear rooms and substations in Karnataka?
Yes. Karnataka's Chief Electrical Inspector requires IS 15652:2006 certified matting for switchboard rooms, transformer bays, substation flooring and distribution panels during mandatory facility inspections. Duratuf XVolt mats carry the ISI mark under BIS approval — the document inspectors ask for.
How do I pick the right XVolt class for my installation?
Class is determined by your system's working voltage. Class A covers up to 3.3 kV, Class B up to 11 kV, and Class C up to 33 kV. Share your voltage rating and we will confirm the right class and dimensions before you order.
Do XVolt mats come with test certificates for PSU and defense procurement in Bengaluru?
Yes. Every XVolt mat ships with the manufacturer's test certificate covering dielectric strength, class and thickness, the documentation that HAL, BEL, BEML and similar PSU purchase orders in Bengaluru typically require alongside the ISI mark.