Electrical Rubber Mat in Hyderabad, Telangana

Buy IS 15652:2006 type-tested, ISI-marked Duratuf XVolt electrical insulating mats for substations, panels, control rooms and other electrical installations across Telangana from Duratuf, a trusted supplier

  • IS 15652 electrical rubber mat blue
  •  IS 15652 electrical rubber mat black
  • IS 15652 electrical rubber mat red

Duratuf XVolt Electrical Rubber Mat

Few Indian cities run as many different kinds of high-voltage electrical environments as Hyderabad. HITEC City, Gachibowli and Nanakramguda run large data centre campuses and IT infrastructure with round-the-clock UPS rooms, generator bays and electrical distribution systems. Patancheru and Genome Valley run pharmaceutical and chemical plants where switchgear operates alongside process equipment. Balanagar and Jeedimetla house dense clusters of engineering and auto-component manufacturers with MCC rooms running through continuous shifts. Adibatla and the HAL corridor handle defense and aerospace facilities with regulated electrical installations. Across all of these, the requirement is the same: an IS 15652-certified mat under every operator working near a live panel.

Duratuf’s XVolt electrical rubber mats are manufactured and type-tested to IS 15652:2006, ISI marked under BIS approval and available in Class A, B and C offering safety up to 36 kV so it matches whatever voltage you are dealing with from a control panel to a full substation. We offer timely and secure delivery across Telangana from our Bhiwadi warehouse and custom sizes are also available if your site needs something different from our standard mats.

✓ ISI Marked ✓ IS 15652:2006 Tested ✓ Class A, B, & C ✓ Custom Sizing Available

Key Features of Electrical Insulating Mats – IS 15652

Every XVolt electrical insulating mat we supply to Hyderabad is type-tested to IS 15652:2006 before it leaves our Bhiwadi warehouse. Whether the requirement is for a data centre electrical room in Gachibowli, a pharmaceutical plant switchgear room in Patancheru or a substation inside a Balanagar manufacturing facility, here is what actually determines whether a mat passes inspection and holds up in service.

ISI Marked

Type tested to IS 15652:2006, ISI Marked approved by BIS

Class A, B & C Ratings

Working voltages of 3.3 kV, 11 kV and 33 kV to match your installation

High Dielectric Strength

Offers exceptional dielectric performance for maximum protection against electrical shock.

Anti-Skid Surface

Engineered with a dotted anti-slip top and textured anti-skid bottom for enhance safety & stability

Wide Temperature Range

Performs reliably from -10°C to +55°C

Standard Sizes and Asthetic Colors

All standard sizes are available as per IS 15652:2006 along with asthetic colors (Black, Blue & Red)

Compliance and Standards

In Telangana, electrical safety matting falls under the Chief Electrical Inspector to the Government of Telangana, a statutory authority under the state’s Energy Department. For HT-connected industrial and commercial industries across Hyderabad, whether a pharmaceutical plant in Patancheru, a data centre campus in HITEC City or an engineering unit in Jeedimetla, the Inspectorate conducts periodic audits that include checking for IS 15652:2006-certified matting in switchgear rooms, transformer bays and panel areas. Duratuf’s XVolt insulating mats are manufactured and type-tested to IS 15652:2006 and carry the ISI mark with BIS approval, which is what inspection officers look for during those facility checks.

View Our Certifications

IS 15652 Electrical Insulating Mats Classes and Voltage Rating

ClassThicknessWorking VoltageAC Proof Voltage Dielectric Strength
A 2.0 mm3.3 kV 10.0 kV 30.0 kV
B2.5 mm 11.0 kV 22.0 kV 45.0 kV
C3.0 mm33.0 kV36.0 kV 65.0 kV
Premium Variant

Also available with Auto-Glow Safety Border featuring a 2" auto-glow strip and 3" high-visibility yellow safety strip along both edges accross the length, clearly defining the safe working area during normal operation and maintaining boundary visibility during power outages or low-light conditions.

IS 15652 Electrical Mat Technical Specification

CharacteristicsValues
Material CompositionElastomer free from any insertion. Typically, a combination of PVC and synthetic rubber polymers.
Antiskid DesignDotted Design
Tensile Strength (T.S.)15 N/mm² (min.)
Elongation at Break (E.B.)250% (min.)
Leakage Current10 mA (max.)
Insulation Resistance with Water when tested at 500 V1,00,000 MΩ (min.)
Flame RetardantExtinguishes within 5 secs (max.)
Ageing Properties at 70±1°C for 168 hoursT.S. & E.B. not less than 75% of original value
Acid, Alkali & Oil ResistanceT.S. & E.B. not less than 80% of original value
Working Temperature-10°C to 55°C
Standard Size1.0 Mtr. Wide x 10.0 Mtr. Long for all classes
Custom Size1.0 Mtr. Wide x Length as per Customer's Requirement up to 30mtr. Long.
Standard ColourBlack, Blue & Red without Metallic Derivatives.

Cut lengths, custom shapes, and colours are available upon request.
Note: Manufacturing tolerance of ±10% on thickness, ±15mm on width & length up to 600mm and ±20mm for higher.

Application of Electrical Rubber Mats in Hyderabad, Telangana

The insulating mats are used in electrical installations where operators deal with live electric devices and the risk of electrical hazards is high. UPS and generator rooms inside data centre campuses, MCC panels in engineering plants, high-voltage receiving stations in pharma units and regulated electrical bays in defense and aerospace facilities. Here is where Duratuf XVolt electrical mats can be deployed across the industries.

  • Electrical Substations
  • HT/LT Control Panel Flooring
  • Switchboard & Switchgear Rooms
  • Transformer Rooms
  • Generator & Lift Rooms
  • Bus Bar Areas
  • Live Equipment Work Areas
  • MCC Rooms
  • Relay & Metering Rooms
  • Distribution Transformer Platforms
  • Cable Junction & Joint Areas
  • Electrical Maintenance & Testing Bays

Working in any of these areas?

Get the right mat class for your voltage requirement.

Why Choose Duratuf for Insulating Rubber Matting in Hyderabad

At Duratuf, we help industries operate more safely and effectively through complaints, technology-driven safety solutions. we Believe that earning a living should never cost a life.

Years of Industrial Safety Expetise

With 16+ years in the business and 4,142+ happy customers across 65+ countries, our insulating mats are already at work.

ISI Marked Manufacturing

Every XVolt mat is manufactured and type-tested to IS 15652:2006, so you get ISI marked matting built to India's electrical safety standard.

Global distribution network

A network of trusted channel partners ensures fast dispatch and reliable delivery, getting the right safety equipment to your site on time.

Brand Reputation

Highly satisfied & loyal clientele base with years of repeat orders

What Our Clients Say

4.8 ★★★★★ Average Rating on Google
★★★★★

"The team has been very responsive and prompt by sharing the required information on the products as well as channel partners"

Jagdeep Saini
★★★★★

"Good experience with Duratuf and good insulating mat as well"

Aliasgar Bharmal
★★★★★

"As an authorized dealer for the Gujarat region, we have had an exceptional experience working with Team Duratuf. Their staff is incredibly polite, highly supportive, and always ready to assist with any queries. The ordering and delivery processes are consistently quick and entirely hassle-free."

Minaxi Industrial Solution
★★★★★

"We are satisfied with the excellent product quality, reliable services, and consistent supply."

Suman Basu
★★★★★

"Quality product and good service"

Fahad Padikkal
★★★★★

"I would like to appreciate the excellent support and professional coordination from your side. Your prompt response and helpful approach are truly commendable."

Subash Chakraborty
★★★★☆

"Good service and polite staff, very satisfied with the service."

Arihant International
★★★★★

"We received the quotation for the rubber mat very promptly, which reflects excellent responsiveness and professionalism. The quick turnaround helped us proceed with our evaluation without delay."

Kuldeep Prajapati
★★★★★

"Your service is good and we have received your product and your follow up is also good."

Max Flow Systems

Frequently Asked Questions

Our HITEC City data centre has large UPS rooms and DG bays. What IS 15652 class applies? +

UPS rooms and DG bays fall under the same IS 15652 class logic as any other electrical installation, it depends on the system voltage, not the type of facility. Most data centre UPS rooms operate at LT levels where Class A (3.3 kV) covers the switchgear. Generator rooms with 11 kV connections need Class B. If your campus has an HT receiving station at 33 kV, that area needs Class C. Share the system voltage for each room and we will confirm the right class before your order.

Exactly where inside a facility should IS 15652 mats be placed? +

The mat goes in front of or directly under any panel, switchboard or equipment where an operator could contact a live electrical component. It must cover the full standing area in front of the equipment, not just a partial strip. Each room with a live panel needs its own compliant mat. One mat at the facility entry does not cover the rest of the installation.

Does Telangana's Electrical Inspectorate check for IS 15652 compliance during factory audits? +

Yes. The Chief Electrical Inspector to the Government of Telangana conducts periodic audits of HT-connected facilities across Hyderabad. Facilities without compliant mats are issued rectification notices that can delay operating clearances.

We Deliver Electrical Safety Mats Across Pan-India

Explore Our Other Electrical Rubber Mats Products

IEC electrical rubber mat

Electrical Rubber Mats
(IEC 61111:2009)

Insulating mats

Switchboard Mats
(ASTM-D178)

Electrical safety mat

Electrical Safety Mat
(EProtect)